Your current location:首页 > Product > Special Explosion Protection Industry Application
Blast-proof infrared intelligent camera
LM-BS580Ex 220VC 5A
Product introduction:
- Two-factor authentication, suitable for a variety of environments
- The case is made of stainless steel
- Vertical installation
- High integration of shield, cradle head, decoder and camera
- Multiple control protocols corresponding to multiple control systems
- Optional infrared LED illuminator or laser illuminator with 360° continuous horizontal rotation +90° ~ -90° vertical rotation
- Protection level IP68
- Contains 128 preset positions
- Indoor and outdoor installation, all-weather use
- Mounted by bracket or base
Technical Parameter:
| Ex-mark | Exd ⅡCT6 / | Automatic heating (optional) | Start automatic heating when the temperature is below -10℃ | 
| DIP A20 TA, T6 | |||
| Material | Stainless steel 304 or 316L | Infrared lamp function | Automatic mode | 
| IP Grade | IP68 | electrical connection | 3-core cable is connected to the power supply | 
| Horizontal rotation | 360°continuous rotation | 2 core cable connection control signal | |
| Vertical rotation | +90°~ -90° | The network outputs a video signal | |
| Horizontal rotation Speed | 0.1°/S ~ 25°/S | Infrared lamp assembly | |
| Vertical rotation Speed | 0.1°/S ~ 25°/S | Light source | Infrared LED/ array LED/ laser illuminator is optional | 
| Unit weight | 28.5Kg | Power Consumption | |
| Gross Weight | 31Kg | LED mode | About 20W | 
| Installation | Fixing bracket, base and column | laser illuminator | Different power lasers are selected according to the projected distance | 
| Electrical Specifications | Projection distance | ||
| · Input voltage | 100VAC~240VAC, 50/60Hz | LED Mode | About 100m | 
| · working current | < 1A | laser illuminator | 100~300m | 
| Power Consumption | About 100 w | Beam Angle | |
| communication mode | RS-485 | Infrared LED | 8° | 
| Cc communication Rate | Multiple, settable | ARRAY LED | 25° | 
| communication protocol | Compatible with a variety of mainstream control protocols | laser illuminator | 2°~15°,According to the projected distance wavelength 850nm/808nm | 
| · Preset Positions | 128 | · Control | Automatic electric | 
| Preset position accuracy | ≤0.1° | ||